Using ChipScope with OPB IIC

XAPP979 (v1.0) February 26, 2007

www.xilinx.com

18

R

Using
ChipScope with
OPB IIC

To facilitate the use of ChipScope to analyze OPB IIC hardware, the

iic.cdc

file is included in

the

ml403_ppc_opb_iic/chipscope

directory. The

iic.cdc

is used to insert a

ChipScope ILA core into the opb_iic core. The following steps are used to insert a core and
analyze OPB IIC problems with ChipScope.

1. Invoke XPS. Run Hardware

→

Generate Netlist.

2. In the

iic.cdc

file, change the path

<design_directory>

name to the directory in which

the design files are installed. Three paths need to be changed.

3. Run Start

→

Programs

→

ChipScope Pro

→

ChipScope Inserter

4. From ChipScope Inserter, run File

→

Open Project ii.cdc.

Figure 22

shows the ChipScope

Inserter setup GUI.

Figure 22: ChipScope Inserter Setup

X979_22_012907