Battery Information

B–12

975-0012-01-02 Rev A

Battery Connections for Stacked Inverters

When using inverters in a stacked configuration, the same battery bank must be
used for both inverters. To ensure even charging of the batteries, each inverter
must be connected to both strings (i.e., positive cable to string two, and negative
cable to string one for inverter 1, and positive cable to string one and negative
cable to string two for inverter 2) as shown in the diagram below.

Figure B-7 Example of Battery Connections for Stacked Inverters (24 Vdc
shown)

DC CONDUIT

FOR

INVERTER 1

(Primary)

+

12 Volt

Battery

200 Ah

+

12 Volt

Battery

200 Ah

+

12 Volt
Battery
200 Ah

Series String 1

Series String 2

DC CONDUIT

FOR

INVERTER 2

(Secondary)

24 VDC/200 Ah

24 VDC/200 Ah

+

12 Volt
Battery
200 Ah

Shunt

Batteries in

Parallel

24 VDC 400 Ah

DC Disconnect

(either a circuit

breaker or a

fuse with a

disconnect)

DC Disconnect

(either a circuit

breaker or a

fuse with a

disconnect)

Advertising