Xantrex Technology DR1524W User Manual

Page 85

Advertising
background image

Specifications of the DR Inverter

975-0012-01-02 Rev A

A–3

DC Input Voltage
(nominal)

c

12.6 Vdc

12.6 Vdc

25.2 Vdc

25.2 Vdc

25.2 Vdc

DC Input Voltage
Range

10.8 to 15.5 Vdc 10.8 to 15.5 Vdc 21.6 to 31.0 Vdc 21.6 to 31.0 Vdc 21.6 to 31.0 Vdc

Auto Low Battery
Protection enabled

11 V

11 V

22 V

22 V

22 V

DC Charger Rate
(Adjustable)

0 to 70 amps

0 to 120 amps

0 to 35 amps

0 to 70 amps

0 to 70 amps

Common Specifications:

Voltage Regulation
(maximum)

± 5%

Voltage Regulation
(Typical)

±2. 5%

Waveform

modified sine wave

Load Power Factor
(allowed)

0.5 to 1.0 (leading or lagging)

Adjustable Load
Sensing Range

5 watts minimum to 100 watts maximum

Series Operation

Yes

Force Air Cooling Variable speed fan

Automatic Transfer
Relay

30 amps

Number of
Charging Profiles

10

Three-stage
Charging

Yes (float, absorption, bulk)

Temperature Comp
Probe (BTS)

optional

Remote Control
(RC8)

d

optional

a.Specifications subject to change without notice.
b.This is the minimum AC current required to obtain full pass-through and maximum battery charging.
c.Product may not meet voltage regulation specifications at other than "Input Nominal" at full-rated load.
d.Also compatible with the RC4.

Table A-1 Electrical Specifications for the DR Inverter/Charger

a

- 120 Vac/60 Hz Models

Model

DR1512

DR2412

DR1524

DR2424

DR3624

Advertising