5 Operating the XPower Inverter

This section explains how to operate the XPower 175 Plus,
XPower 400 Plus and XPower 700 Plus most efficiently.

Operating Conditions and Guidelines

This section describes normal operation as well as conditions that
trigger an alarm or automatically shut down the XPower.

Normal Operation

When you connect the inverter to the vehicle’s

cigarette lighter or directly to the 12 volt outlet and turn on the
On/Off switch, the green

POWER

light illuminates and AC

power is available at the outlets. You can now plug in your AC

products and switch them on one at a time.

Low Battery Alarm and Shutdown

As the battery discharges, its

voltage decreases. When the XPower senses that the voltage at its

DC input has dropped to 10.7 volts, it sounds an alarm. If you
ignore the alarm, and the DC input voltage drops below 10.0

volts, the inverter shuts down all loads to save the battery from

further discharge. The red

FAULT

light comes on.