40

The AC product(s) connected are

rated at less than the inverter’s

continuous power rating; high

starting surge has caused

overload shutdown.

The product exceeds the inverter’s

surge capability. Use a product with

a starting surge power within the

XPower’s capability.

Battery is discharged (alarm is

sounding).

Recharge battery.

The inverter has overheated due

to poor ventilation and has

shutdown (alarm is sounding).

Switch inverter OFF and allow to

cool for 15 minutes. Clear blocked

fan or remove objects covering unit.

Move the inverter to a cooler place.

Reduce load if continuous operation

is required.

Input voltage is greater than 15

volts.

Verify the charging system is

properly regulated and the battery is

12 volts nominal.