The AC load will not operate. No inverter lights are on.

Inverter will run some small loads, but not larger ones.

Possible Cause

Suggested Remedy

Battery is defective.

Check battery and replace if

required.

The inverter has been connected

with reverse DC input polarity.

Check connection to battery. The

inverter has likely been damaged

and needs to be repaired. Have the

unit repaired (not covered under

warranty).

Loose cable connections.

Check cables and connections.

Tighten as required.

Possible Cause

Suggested Remedy

Voltage drop across DC cables.

Shorten cables or use heavier

cables.