TABLE 4: DNP030 COOLING CAPACITIES - 2-1/2 TON

TEMPERATURE

OF AIR ON

CONDENSER COIL

AIR ON EVAPORATOR COIL

1,000 CFM

1,250 CFM

WB °F

WB °F

72

67

62

57

72

67

62

57

85 °F

NET CAP.MBH

33.6

31.6

30.3

30.2

34.5

32.4

31.1

31.0

TOTAL POWER INPUT kW

2.4

2.4

2.3

2.3

2.6

2.6

2.5

2.5

Sensib

le Cap

a

city

MBH

1

En

ter

ing Dry

Bu

lb °F

86

23.6

29.2

30.3

30.2

27.2

32.4

31.1

31.0

83

20.7

26.3

30.3

30.2

23.5

29.7

31.1

31.0

80

17.8

23.4

28.4

29.6

19.7

25.9

31.1

31.0

77

14.9

20.5

25.5

26.7

16.0

22.2

27.3

27.3

74

12.0

17.5

22.6

23.8

12.3

18.5

23.6

23.5

71

N/A

14.6

19.7

20.8

N/A

14.8

19.9

19.8

68

N/A

11.7

16.8

17.9

N/A

11.0

16.2

16.1

95 °F

NET CAP. MBH

32.7

30.5

28.8

28.9

33.5

31.3

29.6

29.7

TOTAL POWER INPUT kW

2.6

2.6

2.6

2.5

2.8

2.8

2.8

2.7

Sensib

le Cap

a

city

MB

H

1

En

ter

ing Dry

Bu

lb °F

86

23.1

29.0

28.8

28.9

26.9

31.3

29.6

29.7

83

20.2

26.1

28.8

28.9

23.1

29.7

29.6

29.7

80

17.3

23.2

27.9

28.4

19.4

26.0

29.6

29.7

77

14.4

20.3

25.0

25.4

15.7

22.3

25.9

26.0

74

11.5

17.3

22.1

22.5

12.0

18.5

22.1

22.2

71

N/A

14.4

19.2

19.6

N/A

14.8

18.4

18.5

68

N/A

11.5

16.3

16.7

N/A

11.1

14.7

14.8

105 °F

NET CAP.MBH

31.0

28.3

27.3

27.3

32.2

29.4

28.3

28.3

TOTAL POWERINPUT kW

2.9

2.9

2.9

2.9

3.1

3.1

3.0

3.0

Sensib

le Cap

a

city

MB

H

1

En

ter

ing Dry

Bu

lb °F

86

22.6

27.6

27.3

27.3

26.4

29.4

28.3

28.3

83

19.6

25.1

27.3

27.3

22.6

28.6

28.3

28.3

80

16.7

22.2

26.4

26.8

18.9

25.1

28.3

28.3

77

13.8

19.3

23.5

23.8

15.2

21.4

24.6

24.6

74

10.9

16.4

20.6

20.9

11.5

17.6

20.8

20.9

71

N/A

13.5

17.7

18.0

N/A

13.9

17.1

17.2

68

N/A

10.5

14.8

15.1

N/A

10.2

13.4

13.4

115 °F

NET CAP.MBH

29.3

26.2

25.7

25.7

30.8

27.5

27.0

27.0

TOTAL POWER NPUT kW

3.2

3.3

3.2

3.2

3.4

3.4

3.3

3.3

Sensib

le Cap

a

city

MB

H

1

En

ter

ing Dry

Bu

lb °F

86

22.0

26.2

25.7

25.7

25.8

27.5

27.0

27.0

83

19.0

24.1

25.7

25.7

22.1

27.5

27.0

27.0

80

16.1

21.2

24.9

25.2

18.4

24.2

27.0

27.0

77

13.2

18.3

22.0

22.2

14.7

20.5

23.3

23.2

74

10.3

15.4

19.1

19.3

10.9

16.8

19.5

19.5

71

N/A

12.5

16.2

16.4

N/A

13.0

15.8

15.8

68

N/A

9.6

13.3

13.5

N/A

9.3

12.1

12.1

125 °F

NET CAP. MBH

27.6

24.1

24.2

24.0

29.4

25.6

25.7

25.6

TOTAL POWER INPUT kW

3.5

3.6

3.5

3.5

3.6

3.7

3.6

3.6

Sensib

le Cap

a

city

MB

H

1

En

ter

ing Dry

Bu

lb °F

86

21.4

24.8

24.2

24.0

25.3

25.6

25.7

25.6

83

18.4

23.2

24.2

24.0

21.6

26.4

25.7

25.6

80

15.5

20.2

23.4

23.6

17.9

23.3

25.7

25.6

77

12.6

17.3

20.5

20.7

14.2

19.6

22.0

21.9

74

9.7

14.4

17.6

17.7

10.4

15.9

18.3

18.1

71

N/A

11.5

14.7

14.8

N/A

12.1

14.5

14.4

68

N/A

8.6

11.8

11.9

N/A

8.4

10.8

10.7

1.

These capacities are net capacities (the indoor fan heat is deducted)

ALL SENSIBLE CAPACITY

Advertising
This manual is related to the following products: