ZyXEL Communications ES-2024 Series User Manual

Page 152

Advertising
background image

Chapter 20 Authentication & Accounting

ES-2024 Series User’s Guide

152

Login

These fields specify which database the Switch should use (first, second and third)

to authenticate administrator accounts (users for Switch management).
Configure the local user accounts in the Access Control > Logins screen. The

TACACS+ and RADIUS are external servers. Before you specify the priority, make

sure you have set up the corresponding database correctly first.
You can specify up to three methods for the Switch to authenticate administrator

accounts. The Switch checks the methods in the order you configure them (first

Method 1, then Method 2 and finally Method 3). You must configure the settings in

the Method 1 field. If you want the Switch to check other sources for administrator

accounts, specify them in Method 2 and Method 3 fields.
Select local to have the Switch check the administrator accounts configured in the

Access Control > Logins screen.
Select radius to have the Switch check the administrator accounts via RADIUS

servers configured in the RADIUS Server Setup screen.
Select tacacs+ to have the Switch check the administrator accounts via TACACS+

servers configured in the TACACS+ Server Setup screen.

Accounting

Use this section to configure accounting settings on the Switch.

Update Period

This is the amount of time in minutes before the Switch sends an update to the

accounting server. This is only valid if you select the start-stop option for the Exec

or Dot1x entries.

Type

The Switch supports the following types of events to be sent to the accounting

server(s):

System - Configure the Switch to send information when the following system

events occur: system boots up, system shuts down, system accounting is

enabled, system accounting is disabled.

Exec - Configure the Switch to send information when an administrator logs in

and logs out via the console port, Telnet or SSH.

Dot1x - Configure the Switch to send information when an IEEE 802.1x client

begins a session (authenticates via the Switch), ends a session as well as

interim updates of a session.

Commands - Configure the Switch to send information when commands of

specified privilege level and higher are executed on the Switch.

Active

Select this to activate accounting for a specified event types.

Broadcast

Select this to have the Switch send accounting information to all configured

accounting servers at the same time.
If you don’t select this and you have two accounting servers set up, then the Switch

sends information to the first accounting server and if it doesn’t get a response from

the accounting server then it tries the second accounting server.

Mode

The Switch supports two modes of recording login events. Select:

start-stop - to have the Switch send information to the accounting server when

a user begins a session, during a user’s session (if it lasts past the Update

Period), and when a user ends a session.

stop-only - to have the Switch send information to the accounting server only

when a user ends a session.

Method

Select whether you want to use RADIUS or TACACS+ for accounting of specific

types of events.
TACACS+ is the only method for recording Commands type of event.

Privilege

This field is only configurable for Commands type of event. Select the threshold

command privilege level for which the Switch should send accounting information.

The Switch will send accounting information when commands at the level you

specify and higher are executed on the Switch.

Table 49 Advanced Application > Auth and Acct > Auth and Acct Setup (continued)

LABEL

DESCRIPTION

Advertising