20.3.2.2 Attributes Used for Accounting Exec Events

The attributes are listed in the following table along with the time that they are sent (the
difference between Console and Telnet/SSH Exec events is that the Telnet/SSH events utilize
the Calling-Station-Id attribute):

20.3.2.3 Attributes Used for Accounting IEEE 802.1x Events

The attributes are listed in the following table along with the time of the session they are sent:

Table 52 RADIUS Attributes - Exec Events via Console

ATTRIBUTE

START

INTERIM-UPDATE

STOP

User-Name

Y

Y

Y

NAS-Identifier

Y

Y

Y

NAS-IP-Address

Y

Y

Y

Service-Type

Y

Y

Y

Acct-Status-Type

Y

Y

Y

Acct-Delay-Time

Y

Y

Y

Acct-Session-Id

Y

Y

Y

Acct-Authentic

Y

Y

Y

Acct-Session-Time

Y

Y

Acct-Terminate-Cause

Y

Table 53 RADIUS Attributes - Exec Events via Telnet/SSH

ATTRIBUTE

START

INTERIM-UPDATE

STOP

User-Name

Y

Y

Y

NAS-Identifier

Y

Y

Y

NAS-IP-Address

Y

Y

Y

Service-Type

Y

Y

Y

Calling-Station-Id

Y

Y

Y

Acct-Status-Type

Y

Y

Y

Acct-Delay-Time

Y

Y

Y

Acct-Session-Id

Y

Y

Y

Acct-Authentic

Y

Y

Y

Acct-Session-Time

Y

Y

Acct-Terminate-Cause

Y

Table 54 RADIUS Attributes - Exec Events via Console

ATTRIBUTE

START

INTERIM-UPDATE

STOP

User-Name

Y

Y

Y

NAS-IP-Address

Y

Y

Y

NAS-Port

Y

Y

Y

Class

Y

Y

Y

Called-Station-Id

Y

Y

Y

Calling-Station-Id

Y

Y

Y

NAS-Identifier

Y

Y

Y

Advertising