Xantrex Technology 1000 User Manual

Page 26

Advertising
background image

Designing Your Installation

975-0127-01-01

3–7

Calculating Size of Chassis Ground Cable

Refer to Table 3-2 to plan the size of the chassis ground cable that runs
from the grounding point to the chassis ground screw on the inverter’s DC
panel.

Table 3-1

Recommended DC Input Wire Sizes & Lengths

RV

a

(Recreational Vehicle)

a. Based on US National Electrical Code NFPA70, Article 551 and Table 310-
17, 90C cables located outside of engine spaces.

Cable length:
Battery to inverter
(one way)

Minimum Cable Size

Maximum Battery
Fuse Size

Less than 5 feet (1.5 m)

No. 2 AWG

150 ADC

Note: Never use a cable longer than 5 feet (1.5 m) with the XPower 1000.
Appropriately sized cable can be bought at a welding supply house or a marine
supply store.

Table 3-2

Recommended Chassis Ground Cable sizes

Application

Chassis ground cable size
(Stranded cable is recommended)

Maximum
Battery Fuse
Size

Recreational Vehicle

a

a. Based on US National Electrical Code NFPA70, Article 551, par. 551-20c.

No. 8 AWG

150 ADC

Note: There are no restrictions on length for the chassis ground cable.

Advertising