10. Before proceeding, double check that the cable you have just installed

connects the positive DC terminal of the inverter to the Disconnect/
Battery Selector Switch, fuse holder, and that the other end of the fuse
holder is connected to the positive terminal on the battery.

.

11. Connect the cable from the negative post of the battery to the negative

DC terminal of the inverter.

12. Install the lock washer and nut that are supplied. Tighten the nut to a

torque of 6–7 lbF-in (0.68–0.79 Nm). Make the connection snug
enough so the ring terminal does not move around on the DC
terminal, but do not overtighten.

13. Use the Disconnect/Battery Selector switch, to select one of the

batteries or battery banks (house bank preferred over start bank).

14. Move the inverter’s On/Off switch to the On position.

The Power light should illuminate, indicating that the XPower 1000 is
ready for operation.

WARNING: Explosion or fire

Do not complete the next step if flammable fumes are present. Explosion or fire
may result if the Disconnect/Battery Selector switch is not in the Off position.
Thoroughly ventilate the battery compartment before making this connection.