Using the Rubber Feet and Stacking Clips

1-15

Figure 1-5

Connect The

UTP

Cable To In-House Lan Connection Box

To connect the OfficeConnect Remote to i

n-house

LAN:

1

Connect the UTP cable (not supplied) into RJ45

socket marked LAN on the OfficeConnect Remote.

2

Connect the other end of the cable into the female

socket of the in-house LAN connection box, as shown

in

Figure 1-5

, or directly to a 10BaseT hub port.

Connecting to a Single Workstation

To connect the OfficeConnect Remote to a single

personal computer or workstation:

1

Implement the crossover for the 10BaseT port on

the

OfficeConnect Remote

by setting the MDI/MDIX

switch to MDIX (out).

2

Connect the UTP cable (not supplied) directly into the

RJ45 socket marked LAN on the

OfficeConnect

Remote

.

3

Connect the other end to the 10BaseT socket on the

workstation’s Ethernet adapter.