Figure 5, Table 4, Ng to each section of – 3Com V7111 User Manual

Page 17: Table 5

Advertising
background image

Figure 5

V7111 Rear Panel Connectors

1

2

3

4

4

5

6

5

Table 4

V7111 Rear Panel Component Descriptions

Item #

Label

Component Description

1

100-240~0.3A max.

AC power supply socket

2

Ethernet

10/100 Base-TX Uplink port

3

RS-232

RS-232 status port (requires a DB-9 to PS/2 adaptor)

4

FXS or FXO

A label that distinguishes between FXS & FXO devices

5

--

2, 4 or 8 FXS / FXO ports

6 Reset

Reset

button

Table 5

V7111 Cables and Cabling Procedure

Cable Cabling

Procedure

Connect the Ethernet connection on the V7111 directly to the network using a
standard RJ-45 Ethernet cable. For connector pinouts, see

Figure 6

RJ-45 Ethernet

cable

.

Note that when assigning an IP address to the V7111 using HTTP (under

Step 1

in

Assigning an IP Address Using HTTP

), you may be required to disconnect this

cable and re-cable it differently.

Connect the RJ-11 FXS connectors to fax
machines, modems, or phones.

Ensure that FXS and FXO ports are
connected to the correct devices,

RJ-11 two-wire

telephone cords

otherwise damage can occur.
The RJ-11 pinouts are described in

Connect the RJ-11 FXO connectors to
telephone exchange analog lines or PBX
extensions.

Figure 6

).

Using a standard RS-232 straight cable (not a cross-over cable) with DB-9
connectors, connect the V7111 RS-232 port (using a DB-9 to PS/2 adaptor) to either
COM1 or COM2 RS-232 communication port on your PC. The pinouts of the PS/2
connector are shown in

RS-232 serial

cable

Figure 8

.

A PS/2 to DB-9 adaptor is not included with the V7111 package. For the PS/2 to DB-9
pinouts, see

Figure 9

.

Connect the V7111 power socket to the mains.

AC Power cable

3Com VCX V7111 Analog Gateway Installation Guide

17

Advertising