oPeration

Cleaning, Care and MaintenanCe

26

| PSH UniverSal el www.Stiebel-eltron.CoM

4.4.8 switching frost protection on/off
If you switch on frost protection, the set temperature is automati-

cally set to 7 °C.
If you switch off frost protection, the set temperature is automati-

cally set to 20 °C.

0

f

f Keep pressing the mode button until

the frost protection symbol appears.

Note

f

f Switch the menu function on using the plus button

or off using the minus button and confirm with the

OK button.

4.4.9 switching rapid heating on/off

Note

You can also switch the function on and off with the rapid

heating button (see chapter "Button functions / Switching

rapid heating on").

0

f

f Keep pressing the mode button until

the rapid heating symbol appears.

Note

f

f Switch the menu function on using the plus button

or off using the minus button and confirm with the

OK button.

5. cleaning, care and maintenance

f

f Never use abrasive or corrosive cleaning agents. A damp

cloth is sufficient for cleaning the appliance.

f

f Check the taps regularly. You can remove limescale deposits

at the tap outlets using commercially available descaling

agents.

f

f Have the electrical safety of the appliance and the func-

tion of the safety assembly regularly checked by a heating

contractor.

f

f Have the protective magnesium anode checked by a heating

contractor after the first year. The heating contractor will

then determine the intervals at which it must be checked

thereafter.

f

f Regularly activate the safety valve to prevent it from becom-

ing blocked by limescale deposits.

6. troubleshooting

Problem

Cause

f

f remedy

The water does not heat

up and the display does

not light up.

There is no power.

Check the fuse/MCB in

your fuse box/distribu-

tion panel.

The water does not heat

up sufficiently and the

heat-up symbol lights

up.

The set temperature is

set too low.

Select a higher set tem-

perature.

The appliance heats,

for example, after large

amounts of DHW have

been drawn.

Wait until the heat-up

symbol goes out again.

The outlet flow rate is

low.

The aerator in the tap or

shower head is scaled up

or contaminated.

Clean and/or descale the

aerator or shower head.

The appliance does not

respond when a button

is pressed.

The key lock symbol is

flashing.

Key lock is enabled.

Disable key lock (see

chapter "Settings / Menu

functions / Enabling/

disabling key lock").

The display flashes.

Notify your local contrac-

tor. Display the fault code

(see chapter "Settings

/ Menu functions / Dis-

playing the fault code").

If you cannot remedy the fault, notify your heating contractor. To

facilitate and speed up your enquiry, please provide the serial

number from the type plate (000000 and 0000-000000):

E-NO.: 000000

F-NO.: 0000-000000