4. Operation

4.1 user interface

1

2

4

3

26

�0

2�

07

�0

09

4

1 ON/OFF indicator light for the booster heater
2 Push button for the booster heater

(only in dual-circuit operation)

3 Temperature selector
4 "SERVICE ANODE" indicator light

!

Possible damage
If the "SERVICE ANODE" indicator light illuminates,
please contact your heating contractor.

The temperature is infinitely adjustable.

cold

E

recommended energy saving position,

low scaling

85 °C maximum set temperature
Depending upon the system, the temperatures may vary from
the set value.

The ON/OFF indicator light illuminates while the water is heated
by the booster heater.

4.2 Instantaneous DHw cylinder operation

following a power failure

Following a longer power failure, you can switch the booster
heater on manually straight away by first turning the temperature
selector to the "cold" position and then up to 85 °C.

4.3 Dual-circuit operation with booster heater

You can switch on the booster heater by means of the push button.
A remote control can also be installed for this purpose. When the
set temperature has been reached, the booster heater switches
off and does not come on again.

5. Cleaning, care and maintenance

»

Never use abrasive or corrosive cleaning agents. A damp cloth
is sufficient for cleaning the appliance.

»

Check the taps regularly. You can remove limescale deposits at
the tap outlets using commercially available descaling agents.

»

Regularly activate the safety valve to prevent it from becoming
blocked by limescale deposits.

»

Have the appliance's electrical safety and the safety assembly's
function regularly checked by a heating contractor.

»

The protective anode must be replaced by the heating contractor
as soon as the "SERVICE ANODE" indicator light illuminates (see
chapter "Maintenance / Replacing the protective anode").

6. What to do if...

6.1 ... the appliance develops faults

fault

Cause

» remedy

The water does not
heat up.

There is no power.

Check the fuse/MCB
in your fuse box/
distribution panel.

The outlet flow rate
is low.

The perlator in the tap or
shower head is scaled or
contaminated.

Clean and / or descale
the perlator or the
shower head.

"SERVICE ANODE"
indicator light
illuminates.

The protective anode
must be replaced.

Notify your local
contractor.

If you cannot remedy the fault, notify your contractor. To facilitate
and speed your enquiry, please provide the serial number from
the type plate (no. 000000-0000-000000):

Nr.: 000000 - 0000 - 000000