9.2.4 Installing the safety assembly

!

Risk of damage
Carry out all water connection and installation works
in accordance with regulations.

»

Install a type-tested safety valve in the cold water supply line.
Be sure to choose the appropriate safety assembly, according
to the relevant static pressure.

»

Size the drain so that water can drain off unimpeded when the
safety valve is fully opened. The blow-off aperture of the safety
valve must remain open towards the atmosphere.

»

Fit the blow-off line of the safety assembly with a constant slope.

»

Observe the information in the installation instructions of the
safety assembly.

9.2.5 Mounting the appliance

26

�0

2�

01

�0

42

4

1

26

�0

2�

01

�0

43

0

1 Cap

»

Fit the caps.

9.2.6 Connecting the power supply

Danger of electrocution!
Carry out all electrical connection and installation
work in accordance with relevant regulations.

Danger of electrocution!
Connection to the power supply is only possible as a
permanent connection. The appliance must be able
to be separated from the mains power supply by an
isolator that disconnects all poles with at least 3 mm
contact separation.

!

Risk of damage
Observe the type plate. The specified voltage must
match the mains voltage.

Earth connection.
Ensure that the appliance is earthed.

26

�0

2�

07

�0

12

7

»

Pull off the temperature selector.

»

Undo the screws.

»

Remove the bottom cap.

»

Pull out the cable grommet at the base while pressing the
snap-in tabs.

»

Push the cable grommet over the power cable and snap the
cable grommet back in place.

»

Connect the power cable to the mains terminal (see chapter
"Specification / Wiring diagrams and connections").