Example program:
; INITIAL TIMER PERIOD COUNTER
; W_LOOP:
MOV AX, 6F02H ;setting the time-out value
MOV BL, 30
;time-out value is 48 seconds
INT 15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP EXIT_AP, 1 ;is the application over?
JNE W_LOOP
;No, restart the application
MOV
AX, 6F02H
;disable Watchdog Timer
MOV BL, 0 ;
INT 15H
;
; EXIT ;