Chapter five: fingerprint registration/enrollment – Acroprint timeQplus Biometric (V2) TQ100 Terminal User Manual

Page 14

Advertising
background image

timeQplus BIOMETRIC™ Terminal User Manual

31

14

timeQplus BIOMETRIC™ Terminal User Manual

Chapter Five: Fingerprint Registration/Enrollment

When the TQ100 terminal and AttendanceRx software installation is complete,

fingerprints will first be enrolled and then validated.

For a network installation with multiple terminals a user’s enrollment is only

needed on one terminal. Any timeQplus administrator can enable the enrolled

user to use any terminal in the network.

5.1 Enrollment Method

Correct enrollment method:

One or multiple fingerprints can be enrolled for every employee.

It is recommended to use the index finger and/or middle finger for enrollment.

Position your finger in the middle of the sensor. Apply light pressure.

Dirty or Dry Finger

Clean your finger with a moisturized soap;

Wipe your finger with a pre- moisturized tissue

(alcohol-free wipes, preferably enriched to

hydrate the skin)

How to choose your finger

Use the index or middle finger to enroll; try left

hand fingers if the right hand (index or middle

finger) fingerprints are faded, worn or missing.

Incorrect positioning

Place your finger in the middle on the sensor;

keep you finger flat on the sensor and apply

pressure trying to cover as much of the sensor

window as possible; DO NOT touch the sensor

in an angled or tilted position, DO NOT slide

your finger.

Fingerprint image changes

Re-enroll your finger if your fingerprint changes

as a result of an injury, etc.

Fingerprint difficult to read

Use one (1:1) identification method. Key in

your PIN number and place your finger on

the sensor.

Other reasons

Use password registration as backup for people
with hard to read fingerprints.

Tips for improving the quality of fingerprint read:

Setup Value

Explanation

Yes/No

Set the door lock option

Factory Setting

No

6. Auto Off
Setup Value

Explanation

1-255

Set the Auto shutdown option

Factory Setting

No

5. Unlock*

*Note: this function is not supported in the AttendanceRx software.

7.2.2 Record Setting

Select Record Setting menu, press OK to enter the level-3 menu as follows:

There are three level-3 menus in Record Setting: Administrator Record Alert,

Total Punches Record Alert and Punch Interval setting, defaulted as per below:

Record
ARecAlert

100

PRecAlert 1000
DupPunches No

Setting Items

Explanation

No

1 - 255

Factory Setting

1. Admin Record Alert

The terminal will not give out an alert when the admin
records have overflowed. If the admin records surpass
the maximum storage capacity, then the terminal will
not store any new admin records. The maximum storage
capacity for administrator records is 1000.

The terminal will give out alert according to the value set
to inform the overflow of management records. If the value is
100, then the alert will be given out from the 900th record.

100

Note: The user is prompted through the message on the display that the

management record space is reaching the maximum capacity.

Advertising