Section 5 – troubleshooting, Error messages -1 scan tool does not power up -1, Error messages – Actron AutoScanner® Plus CP9580A User Manual

Page 99: Scan tool does not power up

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 5 – 1

Troubleshooting

5

Section 5 – Troubleshooting

Error Messages

Check the following if an error message displays:

❒

Verify ignition key is in the ON and not in the ACCESSORIES

position.

❒

Make sure the DLC Cable is attached to vehicle’s data link

connector (DLC) and Scan Tool.

❒

Look at DLC and check for cracked or recessed pins, or for any

substance that could prevent a good electrical connection.

❒

Test for continuity between the DLC wiring and the computer. In

an extreme case, there may be a broken wire.

❒

Check for bent or broken pins.

❒

With the engine off, check for blown fuses in the vehicle fuse box.

❒

Make sure the vehicle’s control module has a good ground. If the

computer case is grounded, then clean the connection and apply

a conductive (dielectric) grease to the mating surfaces.

❒

With the key on engine off (KOEO), verify battery voltage is at

least 8.0V

❒

Verify the control module is not defective. Refer to the service

manual to diagnose the control module.

Scan Tool Does Not Power Up

✓

Review Safety Precautions before troubleshooting.

If Scan Tool will not power up, communicate with vehicle control

module, pass Scan Tool self-tests, or functions incorrectly in any other

way, do the following:

❒

Check and replace the batteries if needed.

❒

Clean the DLC pins.

❒

Disconnect and reconnect DLC making sure it is connected

correctly.

❒

Check vehicle battery to make sure at least 8.0 volts is present.

❒

Contact customer service.

❒

With the engine off, check for blown fuses in the vehicle fuse box.

Advertising