Garmin G1000 Socata TBM 850 User Manual

Page 100

Advertising
background image

Garmin G1000 Pilot’s Guide for the Socata TBM 850

190-00709-00 Rev. A

3-10

ENGINE & AIRFRAME SYSTEMS

Active generator currents are displayed below the generator icons. A disconnected generator is indicated in

gray; the current is removed from the display and the switch symbol is closed.

Switch Open

Switch Closed

Main

Standby

Table 3-1 Generator Switch Status

GPU status information is removed from the electrical diagram when the GPU door is closed. If the GPU door

is open and selected, the GPU status is shown in green; when the door is open, but not selected, the status is
shown in gray with the switch closed. A CAS message, ‘GPU DOOR’ is generated if the GPU door is open.

Battery connection status to the main bus is indicated in green; direction of current flow is indicated with

an arrow next to the current readout. If the battery is disconnected from the main bus, the switch is closed.
Battery overheating is indicated in red with a ‘BAT OVHT’ annunciation; a CAS message is also generated.

Figure 3-16 Battery Overheat Indication

Battery and essential bus voltages are displayed using gauges. Power buses are shown in green when energized.

When not energized, the connection line to the main bus is removed and the bus label is displayed in red.

A red “X” over a component indicates invalid data or a failed unit.