3 osd settings, Genlock error, Disk error – EVS XTnano Version 10.04 - January 2011 Configuration Manual User Manual

Page 13: Audio meters on osd, Audio meters adj.(db), Osd settings, 3 osd, Ettings

Advertising
background image

XTnano – Version 10.04 – Configuration Manual

EVS Broadcast Equipment SA – January 2011

Issue

10.04.A

5

2.2.3 OSD

S

ETTINGS

You can also define the OSD settings on page 1.1 or 5.1 of the setup menu on the
Remote Panel. You will find a description of these settings in the Multicam user
manual.

G

ENLOCK ERROR

Possible values: Yes (default) / No

This function enables or disables the Genlock information on the output monitor.
If Genlock reference is not correct, the “!GkV” message appears on the output
monitor.

D

ISK ERROR

Possible values: Yes (default) / No

This function displays an error message “!Raid” on the output monitor when a disk
is faulty.

Note

The server is equipped with a RAID disk array. This means that the
operation can continue seamlessly even with one faulty disk. If one disk
is disconnected during operation, the “!Raid” message appears on all
output monitors, and another message appears when the operator shuts
down the application, to invite him to replace the disk and rebuild the
RAID array.

Refer to the XTnano Tech Ref Hardware manual for details on the RAID
system and its maintenance.

A

UDIO METERS ON

OSD

Possible values: Yes (default) / No

This parameter enables/disables the display of audio meters at the bottom of each
output monitor.

A

UDIO METERS ADJ

.(

DB

)

Possible range: -83.2 dB to 0 dB. Default 0 dB

This parameter allows adjusting the sensitivity of audio meters on the OSD of the
output monitors. A positive value means that the meters will be more sensitive.

Advertising