12 evs controller settings, 1 effect duration for take, 2 fast jog – EVS XTnano Version 10.04 - January 2011 Configuration Manual User Manual

Page 53: 3 pgm speed/var max, 4 lever engage mode, Evs controller settings, Effect duration for take, Fast jog, Pgm speed/var max, Lever engage mode

Advertising
background image

XTnano – Version 10.04 – Configuration Manual

EVS Broadcast Equipment SA – January 2011

Issue

10.04.A

45

3.12 EVS CONTROLLER SETTINGS

EVS Controller p.6.1
[F1]Effect duration for Take : 00s05fr
[F2]Fast jog : 20x
[F3]PGM Speed/Var Max : 050%
[F4]Lever engage mode : Direct
[F5]Second lever range : -100% <-> +100%
[F6]Recall Clip Toggle : Enable
[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn

3.12.1 E

FFECT DURATION FOR

T

AKE

Possible range: 00s00fr to 20s00fr. Default: 00s05fr

This parameter defines the duration of the transition when using the TAKE key to
chain 2 sequences in PGM+PRV mode.

3.12.2 F

AST JOG

Possible values: 01 to 20 times. Default: 20x

This parameter sets the increment of the jump when in Fast Jog mode.

3.12.3 P

GM

S

PEED

/V

AR

M

AX

Possible values: 1 to 400%. Default: 50%

During playback, if PGM Spd or VarMax has been enabled in the secondary menu
of the Remote Panel, the lever range will be adapted so that:

•

The only playback value for any position of the lever other than 0, is the one
specified by this parameter in the setup (PGM Spd mode ON),

Or

•

The speed range defined by the lever is limited to the value specified by this
parameter (VarMax mode ON).

3.12.4 L

EVER ENGAGE MODE

Possible values: Direct (default) / Current Speed

The speed variation depends on the position of the lever.

Advertising