Ranger™ 3000, Series en-15 – Ohaus RANGER 3000 COMPACT SCALES Manual User Manual

Page 17

Advertising
background image

Ranger™ 3000

Series EN-15

Zero Range

[ZErO]

Set the percentage of scale capacity that may be zeroed.

2%

= zero up to 2 percent of capacity

10% = zero up to 10 percent of capacity

Auto Tare

[A.tArE]

Set the automatic tare functionality.

OFF

= Automatic Tare is disabled

ON

= the first stable gross weight is tared

ON-ACC = stable gross loads within the accept limits are tared (in Check weighing mode)

Beeper Signal

[Bp.sIG]

Set how the beeper responds in Check Weighing mode.

OFF

= the beeper is disabled

ACCEPT = the beeper will sound when the weight is within the Accept range.

UNDER = the beeper will sound when the weight is below the Under setting.

OVER = the beeper will sound when the weight is above the Over setting.

OVER- = the beeper will sound when the weight is below the Under setting or above the

UNDER Over setting.

Beeper Key

[BP.key]

Set whether the beeper sounds when a button is pressed.

OFF

= no sound

ON

= sound

Accumulation

[aCCUmM]

Set the accumulation functionality.

OFF

= accumulation disabled

AUTO = automatic accumulation

MAN

= manual accumulation


End Setup

[End]

Advance to the next menu or return to the top of the current menu.


4.4 Readout Menu

Enter this menu to set user preferences. Default settings are in bold.


Reset:

no

, yes

Stable Range: 0.5, 1, 2, 5

Filter:

low, medium, high

Auto-Zero

Tracking:

off, 0.5, 1, 3

Light:

off, on, auto

Auto off:

off

, 1, 5, 10

End Readout: Exit menu