Velleman VMB1RY User Manual

Page 11

Advertising
background image

Velbus manual VMB1RY– edition 1 – rev.1.0

11

Operation:

The relay module can be operated in different ways:

• Using push buttons connected to the direct push button input:

o

activating the set mode on the module.

• Using push buttons connected to the Velbus

®

through a push button interface or control module:

o

switching on the relay.

o

switching off the relay.

o

switching the relay on or off.

o

activating the set mode on the module.

o

starting or stopping the timer.

o

starting or stopping the 2

nd

timer.

o

starting or restarting the timer.

o

starting or restarting the 2

nd

timer.


LED indication:


The control module LEDs and the operation mode LED on the relay module indicate the status of the relay:

• The LED will not light if the relay is switched off.

• The LED lights if the relay is switched on and the timer is not activated.

• The LED blinks rapidly if the timer is activated.

• The LED blinks slowly if the 2nd timer is activated.


A short press will only be distinguished from a long press in the 2-way timer mode. A short press will activate the
1st timer (TIME1) while a long press will activate the 2nd (TIME2) timer.

Learning Mode:


Only push buttons connected to the Velbus

®

via a push button interface or a control panel are appropriate for the

procedure below.
Each command can accept up to 7 different push buttons.
Memorize he unique address of the module.
Set the module address on:

Address Command

F1

OFF: Learning push buttons switching off the relay

E1

ON: Learning push buttons switching on the relay

D1

TGL: Learning push buttons switching the relay on or off

C1

PBM: Learning push buttons activating the set mode on the module

B1

TG1: Learning push buttons starting or stopping the timer

A1

TG2: Learning push buttons starting or stopping the 2nd timer

91

ST1: Learning push buttons starting or restarting the timer

81

ST2: Learning push buttons starting or restarting the 2

nd

timer


The relay will be switched off and the operation mode LED will blink very rapidly to indicate the learning mode.
The indication LEDs of the learned push buttons will also blink very rapidly. In this way it is possible to see which
push buttons for the corresponding group have already been learned.
You can add a specific push button by maintaining it pressed until the relay switches on. When releasing the push
button the relay will switch off and the push button indication LED will blink very rapidly as a confirmation. If this
does not work then the maximum amount of push buttons has been reached.
To delete a learned push button, maintain it pressed. When releasing the push button the indication LED will be
turned off.
You can delete all learned push buttons for a specific control group by maintaining the manual control on the relay
module pressed until the relay switches on. When releasing the manual control push button the relay and the
indication LEDs of all corresponding push buttons will turn off.
Repeat the procedure above to learn other commands to the push buttons.
Quit the learning mode by resetting the relay module’s original address.
When using firmware version 0736 you will be able to delete all push buttons saved into the memory of the relay
module at once. Set the address to one of the learning addresses. Maintain the manual control on the relay
module pressed for 10 seconds. The relay will activate and deactivate again after 7 seconds to confirm the push
buttons have been erased. Set the address back to its original value.