Velbus manual VMB1RY– edition 1 – rev.1.0

5

CONNECTION

To control a consumer, you can use the relay output’s normal open, normal closed or relay contact.

L

H

PB

-

BUS

VMB1RY

+

12V

-

NO

NC COM COM

N

L

AC POWER

MODE

TIME1

TIME2

ADDR



If the consumer needs a 2-pole interruption (e.g. outdoor lighting, pump) or the consumption exceeds 1000W (e.g.
wall outlets, electric heating, water heater), you need to use an additional 2-pole relay. A 3-phase consumer (e.g.
accumulation heater) has to be controlled through a 4-pole relay.

L

H

PB

-

BUS

VMB1RY

+

12V

-

NO

NC COM COM

N

L

AC POWER

MODE

TIME1

TIME2

ADDR

A1

A2

1

3

2

4

LOAD

1 3

2 4

A1

A2

L

H

PB

-

BUS

VMB1RY

+

12V

-

NO

NC COM COM

N

L1

AC POWER

MODE

TIME1

TIME2

ADDR

A1

A2

3

5

4

6

1 3

2 4

A1

A2

LOAD

6

5

8

7

1

2

7

8

L2 L3

N L1

L2 L3


Connect the 12 … 18VCC (mind the polarity) to the module. Make sure to use a heavier wire gauge (1mm²) with
long connections. You can use the relay output’s normal open, normal closed or relay contact. The relay module
can be controlled via push buttons which are directly connected to the push button input by using the VELBUS or
a combination of both possibilities. te maken van de VELBUS of een combinatie van beide mogelijkheden.