Direct control with several push buttons, Control via velbus system, Velbus manual vmb1ry– edition 1 – rev.1.0 – Velleman VMB1RY User Manual

Page 6

Advertising
background image

Velbus manual VMB1RY– edition 1 – rev.1.0

6

Direct control with several push buttons :

L

H

PB

-

BUS

VMB1RY

PUSH BUTTONS

12V SUPPLY

+

12V

-

NO

NC COM COM

+

-

N

L

AC POWER

MODE

TIME1

TIME2

ADDR


Control via VELBUS system:

L

H

PB

-

BUS

VMB1RY

L

H

12V SUPPLY

BUS
TWISTED
PAIR (0.5mm )

2

+

12V

-

NO

NC COM COM

+

-

N

L

AC POWER

MODE

TIME1

TIME2

ADDR

.

Remark:
To break off communication with the VELBUS system, set the address on ‘00’ so no status modifications will
be reported. All learned push buttons must be deleted (see learning mode) so no instructions will be sent over
the VELBUS to control the push button indication leds.
In the other case, de relay module will cause a bus error with every status modification.

Remark: For connection between the modules, use twisted pair cable (ex. EIB 2x2x0.8mm2, UTP 8x0.51mm -
CAT5 or other). Use minimum 0.5mm² cable. For long wiring (>50m) or if a lot of modules ( > 10) are
connected to one wire, use 1mm² cable.
Connect the bus (mind the polarity) to the module.