3features – Velleman VMB1RY User Manual

Page 3

Advertising
background image

Velbus manual VMB1RY– edition 1 – rev.1.0

3

Features:









◊ Relay output: changeover contact (N.O. and N.C.)

◊ Switching capacity with a resistive load: 16A/230Vac max.
◊ Switching capacity with an inductive load: 8A/230Vac max.

◊ Suppressed relay contacts.
◊ Manual control on the module

◊ LED indicators for:

• Relay output

• Operation modes (slow, fast, very fast or 2 x blinking and continuously ON)

• Power voltage

• Data reception and forwarding through VELBUS

◊ 10 different operation modes (adjustable through ‘mode’l rotary switch):

• Moment control

• On/off control

• Start/stop timer

• Staircase lighting timer

• Non-restartable timer

• Switch-off delay

• Switch-on delay

• Start timer by releasing push button

• Timer with blinking effect

• 2-way timer (short press will start timer 1/ long press will start timer2)

◊ 16 possible time settings (adjustable through ‘time1’ rotary switch): moment - 5s - 10s - 15s - 30s - 1min - 2 min

- 5min - 10min - 15min - 30min – 1h – 2h – 5h – 1day – on/off

◊ 9 possible time settings for timer 2 (adjustable through ‘time2’ rotary switch): 5min - 10min - 15min - 30min – 1h

– 2h – 5h – 1day – on/off

◊ Controllable by connecting several push buttons in parallel.

◊ Push button input debounce: 65ms.
◊ Control through VELBUS.

◊ Programmable without PC.

◊ Easy learning process by controlling the push buttons in the learning mode.
◊ 8 different control possibilities:

• Using push buttons turning on the relay.

• Using push buttons turning off the relay.

• Using push buttons turning the relay on or off.

• Using push buttons activating the set mode on the module.

• Using push buttons starting or stopping the timer.

• Using push buttons starting or stopping the 2nd timer.

• Using push buttons starting or restarting the timer.

• Using push buttons starting or restarting the 2nd timer.

◊ Memory for 7 different push buttons per command

◊ Learned push buttons are saved in case of a power failure.
◊ Report to control modules for LED status modification.

◊ 247 possible addresses (adjustable through ‘ADDR” rotary switch)
◊ Required power voltage: 12 to 18VDC

◊ Consumption in standby: 35mA at 18V (15mA at 16V)
◊ Consumption activated relay: 85mA at 18V (60mA at 16VDC)

◊ Max. consumption (activated relay and push button input): 100mA at 18V (75mA at 16VDC)

◊ Standard DIN-rail housing (2 modules)
◊ Dimensions (L x W x H): 90 x 36 x 58mm.

◊ Weight: 100g.