34.

For automatic

transmission only: Insert
the end of the provided Tcc wire
harness with the 4-pin connector
through the grommet from the
engine compartment side using
the same hole. Pull the Tcc wire
harness from inside the cab until
approximately 18” of the harness
is inside. Note that the Tcc wire
harness is not applicable on vehicles
with a manual transmission.

NOTE: Taping the end of the
harness to a piece of stiff wire (i.e.
coat hanger) may make routing
the harness through the firewall a
simpler task. The stiff wire should
be pushed through the slit in the
grommet and then the wires can be
attached to the stiff wire and pulled
through the hole in the firewall.

35.

In the engine compartment,

locate the cAN BUS connector on the
left hand’s side of the engine:
FOR 1998.5 TO 2000
VEHICLES
: The cAN BUS
connector is triangular shaped and
near the power steering pump.
Remove the weather seal plug. Insert
the Ottomind wire harness cAN
BUS connector into this connector.
However for some 1999 and 2000
vehicles, the CAN BUS connector
could be a flat 3-pin connector.
Use the provided cAN BUS adapter
wire and plug it into the triangular
connector on the OttoMind wire
harness, then follow 2001-2002 CAN
BUS installation procedure.
FOR 2001 TO 2002
VEHICLES
: The cAN BUS

connector is a flat 3-pin connector
locates on top of the fuel lift pump
below the Manifold Absolute
Pressure (MAP) sensor. Remove

the weather seal plug and insert
OttoMind cAN BUS connector into
this connector.