Grain Systems PNEG-1472 User Manual

Page 25

Advertising
background image

4. Installation Instructions

PNEG-1472 L & B Series Field Installation

25

6. Vaporizer Plumbing Assembly (LP models only)

The vaporizer plumbing assembly is installed as follows (LP models only). Refer to Figures 4J, 4K, and
4L.

1. Install the vaporizer assembly and vaporizer support bracket into dryer heating plenum.

2. Starting from the vaporizer, assemble the pipe subassemblies. Fully tighten all pipe joints as you

proceed. Use a teflon paste pipe sealer on fuel pipe threads.

3. See installation Step 7, Electrical Wiring, for attaching and wiring vaporizer conduit assembly.

4. The liquid propane supply line may now be attached. Propane should be supplied at tank pressure

to the vaporizer plumbing inlet ball valve.

Figure 4J Vaporizer plumbing for 3020L (C2130B), and 4026L (C2140B).

Advertising