4. Installation

PNEG-1283 Moisture Sampler

11

Figure 4G

18. Install sheave (018-1047-2) and bushing (D32-0016) on the bottom auger shaft that extends

through the discharge box. The key that comes with the bushing is not needed for this installation.
Slide bushing into the sheave (leave loose, do not force the bushing in). Slide sheave and bushing
onto the auger shaft. Insert bushing bolts through the non-threaded holes of the bushing (threaded
holes are for bushing removal) and thread into the holes of the sheave. Tighten bolts evenly until
bushing is snug against the auger shaft but still loose enough to slide on auger shaft so that its
position can be adjusted in a later step.

Figure 4H

Auger shaft

Flangette

Bearing

Discharge box
bearing plate

Lock collar