4. Installation

8

PNEG-1283 Moisture Sampler

3. Disconnect the tilt switch and remove conduit from the discharge box.

(See Figure 4C.)

Figure 4C

4. Remove the discharge box assembly from the dryer by removing eight (8) 5/16" bolts, then sliding

the discharge box off the discharge auger.

5. Remove the standard grain sampler from the discharge box assembly auger tube.

6. Hold the Moisture Sampler assembly up to the side of the discharge box assembly. Square the

drive end of the Moisture Sampler with the overlapping edge of the discharge bearing plate and
the bottom edge of the discharge side panel.

(See Figure 4D.)

Mark the location of the three (3)

bolt holes.

Figure 4D

7. On the discharge side plate at the drive end of the Moisture Sampler drill three (3) 3/8" holes at the

marks made in

Step 6

.

8. Using a sheet of paper make a template of the back side of the mounting plate on the drive end of

the Moisture Sampler. Use this template to mark the square hole in the discharge side panel.
Including the three (3) bolt holes in the template will help to ensure correct hole alignment.

9. Cut out the square hole marked out in

Step 8

.

Tilt switch

Discharge bearing plate

Discharge side panel

Square up here