Operating procedure – Grain Systems PNEG-591 User Manual

Page 17

Advertising
background image

17

Series 2000 Downwind Heater

OPERATING PROCEDURE

2

4

6

8

10

12

14

15

ALL
MODELS

816,013

1,148,640

1,409,477

1,632,026

1,825,859

1,995,762

2,153,700

2,227,883

Fan

Static

Model

Pressure

60

80

100

120

140

160

180

2"

2

4

6

8

10

13

10 hp

4"

1

3

5

6

8

11

14

6"

1

1

3

5

6

8

10

2"

3

6

9

12

15

15 hp

4"

3

5

7

10

13

6"

2

3

5

6

9

11

14

Gauge Pressure (psi) Required to Maintain Temperature (Approximate)

(10-15 hp High Temperature Propane Units Only)

Heat Rise (°F)

10-15 hp Units

BTUs Per Gauge Pressure (psi) PROPANE MODELS (Approximate)

OPERATING PRESSURE (psi)

High Temperature 10-15hp 7/32" (0.219") Orifice

1

2

3

4

5

6

7

ALL
MODELS

859,104

1,218,432

1,489,296

1,718,208

1,921,584

2,107,632

2,276,352

Fan

Static

Model

Pressure

60

80

100

120

140

160

180

2"

1

1.75

2.5

3.5

4.75

6

10 hp

4"

0.75

1.25

2

2.75

3.75

4.75

6

6"

0.5

1

1.5

2

2.75

3.5

4.25

2"

1.5

2.5

3.75

5.5

15 hp

4"

1.25

2

3

4.25

5.75

6"

0.75

1.25

2

2.75

3.75

5

6

OPERATING PRESSURE (psi)

Gauge Pressure (psi) Required to Maintain Temperature (Approximate)

(10-15 hp High Temperature Natural Gas Units Only)

Heat Rise (°F)

10-15 hp Units

BTUs Per Gauge Pressure (psi) NATURAL GAS MODELS (Approximate)

High Temperature 10-15hp 11/32" (0.344") Orifice

Advertising