Operating procedure, Adjusting the vaporizor, Running the dryer – Grain Systems PNEG-591 User Manual

Page 22

Advertising
background image

22

Series 2000 Downwind Heater

Adjusting the vaporizer coil on a liquid propane model. The top photo

shows the setting in, and the bottom photo shows the coil out.

Adjusting The Vaporizor

The display will indicate "FLAME"

when flame is sensed. If no flame

is sensed, the "FLAME" message

will be off. The display indicates

what part of the cycle it is in. If the

unit is a hi-lo dryer, the display will

indicate whether it is in the "HI-

FLAME" or "LO-FLAME" part of

the cycle. (See "programming set

points" page 21 for setting the hi-lo

flame temperature). If the tempera-

ture is above the high temperature set-

ting, the flame will be off, the

"FLAME" message will be out and the

display will be flashing "OFF-

CYCLE".

If the flame is shut off because

of the humidity sensor (humidistat),

the display flashes "OFF-CYCLE

HUMIDISTAT".

Running The Dryer

1. Vaporizer should be adjusted so

the vapor pipetrain runs warm

to the touch (100°-120°F).

2. Loosen 5/16" bolt on adjust-

ment bracket.

3. Swivel vaporizer away from

flame if running too hot, closer

to flame if too cold.

4. Move vaporizer only 1" at a time

and allow a few minutes for

tem perature to equalize.

5. Tighten 5/16" bolt and watch

heater run for several minutes

to verify adjustment.

OPERATING PROCEDURE

Advertising