23

Series 2000 Downwind Heater

Programming Set Points

Multiple heaters may be done at any heater control console. The informa-

tion programmed is automatically transmitted to all other heaters when the

programming is complete.

Hi Limit Set Point--The upper left cursor is flashing indicating the

mode. If the plenum temperature increases above this point, the flame is

shut off--"OFF-CYCLE" is displayed on screen.

Cycle Set Point--The upper 2nd from left cursor is flashing indicating

the mode. If the dryer is not a hi-lo dryer, this function is skipped. If

the plenum temperature increases above this point, the flame reduces to

"LO-FLAME".

Humidity Set Point--The upper 2nd from right cursor is flashing indi-

cating the mode. If the humidity is above this point the dryer operates

Depressing the "PROGRAM"

switch (lower left) causes the dis-

play to enter the program mode.

Each item below is programmed by

using the up and down arrow

switches. Holding down these up

and down arrow switches for about

2 seconds will cause the numbers to

increase/decrease rapidly until the

switch is released. When finished

programming an item, depressing

the "PROGRAM" switch again will

cause the new setting to be entered

into memory, and the display will

advance to the next function to be

programmed.

Programming may be done at

anytime (unless an error condition

exists) even while the dryer is in

operation.

Programming a system with

The limits are continuously

checked during the drying operation.

A limit switch open or any other er-

ror condition will cause the dryer to

shutdown, and the fan will be shut-

down. If a limit opens, or an er-

ror condition occurs during dry-

ing, the control will lockup in the

error display mode. Power must

be shut off and back on to the con-

trol to clear the error condition--

even if the error or limit that

caused the shutdown has been

corrected. This is to keep the dis-

play locked up with the condition

that caused the error, allowing the

operator time to determine what

caused the shutdown.

normally--flame on and off at the high limit and cycle set points. If the

humidity is below this point the dryer goes into the "OFF-CYCLE" mode.

Temperature Differential--The upper right cursor is flashing indicating

the mode. If the flame shuts off because the temperature is greater than the

high limit set point, the temperature must fall below the (Set Point minus

Temperature Differential) for the flame to come back on.