Grandstand support requirements for above floors – Grain Systems Bin Flooring PNEG-529 User Manual
Page 16
Advertising
![background image](/manuals/277656/16/background.png)
6. 345 Cut-Lok/20 Gauge Cor-Lok Floors for Non-GSI Bins
16
PNEG-529 Cor-Lok and Cut-Lok Flooring for Non-GSI Bin Diameter
Grandstand Support Requirements for Above Floors
Spacings and quantities of supports are shown below.
Diameter
6 Rings (16' 8 Eave)
7 Rings (19' 5 Eave)
8 Rings (22' 2 Eave)
Nom.
Act.
Spacing
# of Supports
Spacing
# of Supports
Spacing
# of Supports
19'
(18' 7)
52/26
136
50/25
140
48/24
144
22'
(21' 8)
52/26
177
48/24
188
46/23
194
25'
(24' 9)
50/25
238
48/24
245
44/22
262
28'
(27' 10)
50/25
300
46/23
320
44/22
330
31'
(30' 11)
50/25
370
46/23
390
44/22
410
34'
(34' 0)
48/24
460
46/23
480
44/22
490
38'
(37' 1)
48/24
550
46/23
560
42/21
610
41'
(40' 2)
48/24
640
44/22
680
42/21
710
44'
(43' 3)
46/23
770
44/22
790
42/21
820
50'
(49' 5)
46/23
1000
42/21
1070
42/21
1070