Air flow support installation – Grain Systems Bin Flooring PNEG-529 User Manual

Page 30

Advertising
background image

11. Air Flow Support Installation

30

PNEG-529 Cor-Lok and Cut-Lok Flooring for Non-GSI Bin Diameter

Installation, Spacing and Quantities of Air Flow Supports Under

Channel Lock Floors York and Chief Bins

Bin Diameter - Number of Supports

Grain Depth at

Bin Wall (ft.)

Spacing

(in.)

15' 6"

18' 7"

21' 8"

24' 9"

27' 10"

Full Double Single Full Double Single

Full Double Single Full

Double Single Full Double Single

18'

30"

26

2

8

36

2

8

50

2

10

64

2

12

80

2

14

24'

26"

30

2

8

42

2

8

56

2

10

74

2

12

92

2

14

27'

24"

32

2

8

44

2

8

60

2

10

78

2

12

98

2

14

32'

20"

38

2

10

52

2

10

72

2

12

92

2

14

116

2

16

40'

16"

46

10

14

64

12

14

86

14

16

114

14

18

142

16

20

48'

13"

54

10

16

78

12

16

106

14

20

136

14

22

172

16

24

53'

12"

58

10

18

84

12

18

114

14

22

148

14

24

184

16

28

68'

10"

70

10

22

98

12

22

134

14

26

174

14

28

220

16

32

16'

24" and 12"

60

10

8

72

12

8

88

14

10

106

14

12

126

16

14

(for Grain Flow)

Bin Diameter - Number of Supports

Grain Depth at

Bin Wall (ft.)

Spacing

(in.)

31'

34'

37' 1"

40' 3"

43' 4"

Full Double Single

Full

Double Single

Full Double Single Full Double Single

Full Double Single

18'

30"

98

2

14

116

2

16

136

2

18

160

2

20

182

2

22

24'

26"

112

2

14

132

2

16

154

2

18

182

2

20

208

2

22

27'

24"

120

2

14

142

2

16

166

2

18

196

2

20

224

2

22

32'

20"

140

2

18

168

2

20

198

2

22

232

2

26

260

2

26

40'

16"

174

18

22

208

20

24

244

22

28

286

24

32

330

26

32

48'

13"

210

18

28

252

20

30

298

22

34

350

24

38

402

26

38

53'

12"

228

18

30

272

20

34

316

22

36

378

24

42

434

26

42

68'

10"

270

18

36

324

20

40

384

22

44

450

24

50

520

26

50

16'

24" and 12" 148

18

14

170

20

16

194

22

18

224

24

20

252

26

22

(for Grain Flow)

Bin Diameter - Number of Supports

Grain Depth at

Bin Wall (ft.)

Spacing

(in.)

49' 6"

55' 8"

61' 10"

Full

Double

Single

Full

Double

Single

Full

Double

Single

18'

24"

288

2

28

362

2

32

444

2

36

24'

20"

346

2

28

436

2

32

536

2

36

27'

20"

346

2

28

436

2

32

536

2

36

32'

20"

346

2

28

436

2

32

536

2

36

40'

16"

428

28

36

540

32

42

664

36

46

48'

13"

524

28

44

660

32

52

812

36

56

53'

12"

566

28

48

714

32

54

878

36

60

68'

10"

676

28

58

852

32

68

1050

36

72

Advertising