Fuel connection liquid propane models, Propane vapor models, Natural gas models – Grain Systems PNEG-588-04 User Manual

Page 17

Advertising
background image

5. Installation

PNEG-588-04 Deluxe Downwind Heater Installation and Operation

17

Fuel Connection

Liquid Propane Models

1. LP models are designed to run on liquid propane, with liquid draw from the propane tank. Avoid using

propane supply tanks that have been use for vapor draw for long periods of time. When using liquid
draw systems any moisture that may be present in tank or lines may freeze when system is used in
cold weather. To avoid this, the usual precaution is to purge the system with methanol.

2. Run proper size line

(See Specifications on Page 9)

to pipe train on heater. Have a qualified gas

service person inspect installation to be sure everything is installed according to local codes
and ordinances.

3. After installation is complete, check all connections for leaks. Use liquid detergent or comparable

substance. Wear rubber gloves and eye protection. Avoid contact with liquid propane.

Propane Vapor Models

1. Propane vapor models are designed to run directly off of supply tank or from a separate

external vaporizer.

2. Run proper size line

(See Specifications on Page 9)

to pipe train on heater. Have a qualified gas

service person inspect installation to be sure everything is installed according to local codes
and ordinances.

3. After installation is complete, check all connections for leaks.

Natural Gas Models

1. Natural gas models are similar to vapor models, but have a larger orifice to accommodate lower

pressure, sometimes found with natural gas.

2. Run proper size line

(See Specifications on Page 9)

to pipe train on heater. Have a qualified gas

service person inspect installation to be sure everything is installed according to local codes
and ordinances.

3. After installation is complete, check all connections for leaks.

Do not use propane tanks which have previously been used for ammonia unless
they have been purged according to procedures of the national LP association.

Investigate to be sure that the fuel supply system complies with all local codes for
LP gas installations.

CAUTION

Do not use flame for leak testing.