Attaching vertical to bin (continued) – Grain Systems Unload Augers PNEG-1079 User Manual

Page 13

Advertising
background image

4. Assembly Instructions

PNEG-1079 6", 8" and 10" Vertical Bin Unload Auger

13

Attaching Vertical to Bin (Continued)

5. Using the same U-bolts and nuts, attach ears and half band to vertical tube at the same. For maximum

stability, locate the bands on the upper half of the tube.

(See Figure 4B.)

6. Bolt telescoping tubes to the ears using two (2) 3/8" x 1" bolts and nylock nuts.

(See Figure 4B.)

Figure 4B

7. Secure telescoping tube inside of tube at appropriate length with 3/8" x 3/4" hex head set screws.

8. Attach telescoping tube to bin structure. (Hardware not included.)

9. Assemble spout to vertical auger over discharge opening with half band using 5/16" x 1-3/4"

hex head cap screws and lock nuts.

Advertising