Operation & maintenance – Grain Systems Unload Augers PNEG-1057 User Manual

Page 26

Advertising
background image

Operation & Maintenance

18

8" & 10" Commercial Vertical Bin Unloading Auger - PNEG 1057

3. Power Source

A. Use electric motors that operate at 1750 R.P.M.

B. Electric motors and controls should be installed by a qualified electrician and must meet the standards set by

the National Electrical Code and all local and state codes.

C. A magnetic starter should be used to protect your motor when starting and stopping. It should stop the motor in

case of power interruption, conductor fault, low voltage, circuit interruption, or motor overload. Then the motor
must be restarted manually. Some motors have built-in thermal overload protection. If this type motor is used,
use only those with a manual reset.

You should use a Main Power Disconnect Switch capable of being locked only in the

OFF position. This should be locked whenever work is being done on the auger.

Disconnect power before resetting motor overloads.

Make sure all electrical motors are grounded.

Reset and motor starting and stopping controls must be located so that the operator has

full view of the entire operation.

Shut off power to adjust , service, or clean the machinery.

Keep all safety guards and shields in place.

4. Maintenance

A. The flange bearings on the head and tail ends of all units should be lubricated on frequent intervals.

Never clean, adjust, or lubricate a machine that is in operation.

Advertising