Troubleshooting

20

8" & 10" Commercial Vertical Bin Unloading Auger - PNEG 1057

Problem

Possible Cause

Solution

1. The auger is vibrating.

A.

Damage can occur to the

auger flighting, causing noise.
Damage usually is caused
from foreign material being run
through the auger.

A1. It may be necessary to remove the

flighting for inspection.

2. Capacity is too low.

A.

There may not be enough grain

reaching the auger.

A1. Make sure the intake has not

bridged over, restricting flow. The
flighting at the intake should be
covered with grain for maximum
capacity.

B.

The auger is moving too slowly.

B1. Check the auger speed. Low

capacity will result from speeds
slower than recommended.

3. The auger plugs.

A.

The auger may be "jamming"

because too much grain is
reaching the auger.

B.

The grain may be wet.

B1. If wet grain or other hard-to-move

material is being augured, use a
larger size motor than recom-
mended for normal use.

C.

The auger may be jammed

with foreign material.

C1. Remove any foreign material in the

auger.

D.

The motor may be to small or

wired incorrectly.

D1. Check wiring or consider using the

next larger size motor.

A1. Use the control gates to decrease

the amount of grain the auger is
gathering.

A.

Drive belt may be overtightened,

putting head stub and flight in a
bind.

A1. Loosen the drive belts.