11. FINAL CLEAN-OUT

The following procedure is recommended for cleaning the
floor of the bin after the sweep auger has removed as
much grain as possible.
1.

Lockout all power.

2.

Clean (scoop and sweep by hand) the outer area of

the floor into a circular pile towards the center of the

bin. (See Fig. 28)

3.

Get out of the bin.

4.

After making sure everyone is outside the bin and

clear of the equipment, start the under floor unloader

and the sweep auger. In a short time, the circular pile

towards the center of the bin will have been removed.

DO NOT enter a grain bin unless all power driven equipment has been shut down and
locked out.

Keep out of bin while sweep is in operation! The sweep auger will move rapidly around
the bin when the bin is nearly empty.

FIG. 28

FIG. 29

TOP VIEW OF BIN

SWEEP
AUGER

BIN WALL

BIN WELLS

CLEANED AREA

REMAINING GRAIN

SWEEP
AUGER

BIN WALL

BIN WELLS

5.

Stop the equipment and lock out all power.

6.

Scoop and sweep by hand the remaining floor area to

the center of the bin. (See Fig. 29)

7.

Get out of the bin.

8.

Repeat steps 3, 4, 5, and 6 until all grain has been

removed from the bin.