Grain Systems PNEG-1458 User Manual

Page 32

Advertising
background image

6. Vision Touch Screen Display

32

PNEG-1458 T-Series Tower Dryer

4. BPH Calibration: Touching the BHP Calibration button will display the Unload Bushels Setup

screen.

(See Figure 6M.)

As you can see the bushel counter can be cleared by touching the

Clear button. However if the bushel counter is out of calibration it can be calibrated by touching
the Increase and Decrease buttons.

Example: If you ran 1000 bushels through the dryer but the bushel counter on the dryer reads
900 bushels then touch the Decrease button until the calibration reads 90% or if you ran a
1000 bushels and the counter reads 1100 bushels then touch the Increase button until the
calibration reads 110%.

When you are finished with the calibration or clearing the bushel counter touch the Accept
button to return to the Hardware Setup Parameter screen.

Figure 6M

5. Set Time/Date: Touching the Set Time/Date button will display the Set Time/Date window.

Use the up and down buttons to change each of the parameters for date and time. Touch
Accept/Exit to save settings and return to the Select Hardware Parameter to Modify screen.

Figure 6N

Advertising