8. Dryer Operation

PNEG-1458 T-Series Tower Dryer

39

Figure 8B

Setting the Temperatures

Setting the temperature set points for the dryer is a simple procedure. To adjust the temperature
set points touch the

button at the bottom of Operation screen. A new screen will appear called the

Select Temperature Set Point to Modify screen.

(See Figure 8C.)

As you can see you modify the set point

for the plenum by touching the Plenum 1 Temperature button.

The plenum temperature set point range is 80°F-250°F and the current temperature set point for each
plenum is displayed next to the corresponding Plenum button.