Test firing, Chapter 7 test firing, Dryer pre-season checks – Grain Systems PNEG-1458 User Manual

Page 34: Inspect the accutrol metering system, Electrical power, Control power switch, Start switch, Fuel check

Advertising
background image

34

PNEG-1458 T-Series Tower Dryer

7. Test Firing

Dryer Pre-Season Checks

This section gives a series of checks to be carried out on the dryer before starting for the first time in the
drying season. If any of the checks fail to produce the stated result, you should consult your dealer.

You should not attempt to use the dryer unless all the pre-start checks have been successfully completed.

Inspect the Accutrol Metering System

Open the two (2) access doors and inspect the accutrol sweep metering system to ensure that the system
is free of foreign material.

Electrical Power

Turn ON the electrical power supply to the dryer, set all circuit breakers to ON, including the safety
disconnect handle mounted on front of the dryer power panel.

Control Power Switch

Turn the Control Power switch to ON. At this point the controller will lock out all other dryer functions.
Once the Boot screen appears

(See Page 24)

, touch the Start Dryer button and the dryer will perform

a safety circuit check. If a fault is found, the cause will be displayed on the Main screen. If all are found
safe, the Start switch will illuminate, indicating that the dryer is ready to be started.

Start Switch

Push the Dryer Start switch and all the selector switches on the control panel will be activated.

Fuel Check

If using LP gas, make sure the tank has plenty of fuel and that the tank does not have a regulator mounted
on the liquid line. Slowly open the main fuel supply valve at the tank. Then, open the manual shut off valve
on the dryer to allow fuel flow to the dryer.

If using natural gas, make sure an adequate supply at 10 PSI of pressure is available. Turn ON the valve
along the supply line. Inspect all gas lines and connections for possible leaks.

WARNING

Before attempting to operate the dryer make sure all safety shields are in place,
all access doors are closed and all personnel are clear of the dryer.

WARNING

Any gas leaks must be fixed immediately.