2.66" commercial tank roof instructions, Chapter 9 2.66" commercial tank roof instructions, Roof beam stiffener sidewall attachment – Grain Systems Tanks PNEG-2135 User Manual

Page 50: Roof beam stiffener and bracket attachment, Eave clip attachment

Advertising
background image

50

PNEG-2135 Construction Manual for 2.66" Corrugation 135' Diameter Tank

9. 2.66" Commercial Tank Roof Instructions

Roof Beam Stiffener Sidewall Attachment

Attach the roof beam stiffener (CRP-6363) to the sidewall using 3/8" x 1-1/2" bin bolt (S-5060) and
nut (S-456). Next, field drill four (4) extra holes in the sidewall to match the beam stiffener. Place a
corrugation spacer (S-7041) and a steel backed neoprene washer between the beam stiffener and
sidewall at each hole location (8X total).

(See Figure 9A.)

Roof Beam Stiffener and Bracket Attachment

Attach roof beam stiffener (CRP-6363) and bracket (CRP-6364) together in five (5) places using
3/8" x 1" bin bolt (S-455) and nut (S-456).

(See Figure 9A.)

Eave Clip Attachment

Attach intermediate eave clip (CRP-5327) and standard eave clip (CRP-5325) with 5/16" x 1-1/4"
bin bolt (S-277) and flange nut (S-3611).

(See Figure 9A.)

Figure 9A

Advertising