10. 2.66" Commercial Tank Accessories Installation

PNEG-2135 Construction Manual for 2.66" Corrugation 135' Diameter Tank

77

Ladder Section Assembly

Two (2) LDR-4317 splice plates are required to attach each ladder section. The head of the bolt should
be to the inside of the ladder with the splice plate on the outside as shown. Use 5/16" x 3/4" bolts for
all connections.

(See Figure 10N.)

NOTE: With most installations, the last ladder section installed to reach either the ground or the

intermediate platform will need to be cut to fit.

Figure 10N