Assembly – Grain Systems Tanks PNEG-2135 User Manual

Page 68

Advertising
background image

10. 2.66" Commercial Tank Accessories Installation

68

PNEG-2135 Construction Manual for 2.66" Corrugation 135' Diameter Tank

Assembly

1. Turn one roof vent housing (MIS-6778) upside down.

(See Figure 10C.)

2. Insert 5/16" x 1-1/4" bin bolt with neoprene washer through the hole in the side of the roof vent. Place

jamb nut onto the bolt and tighten.

(See Figure 10C.)

3. Slide one eyelet of grill guard onto the 5/16" bin bolt.

4. Insert 5/16" x 1-1/4" bin bolt with neoprene washer through the other side of the roof vent, through

jamb nut and other eyelet of grill guard. Tighten nut against vent housing side.

5. Apply a bead of tube caulking around the three (3) housing sides of the roof vent where it meets the

hold-down angle.

6. Place hold-down angle (MIS-4404) on the assembled roof vent. The wide end of the hold-down angle

must face the vent discharge. Once aligned, screw nine (9) #10 self-drilling screws (S-280) through
the roof housing and into the hold-down angle.

(See Figure 10D.)

Figure 10C

Figure 10D

Advertising