Connecting to 3-wire phoenix terminal connectors, Installation and setup – Cobalt Digital COMPASS 9391 3G_HD_SD-SDI Timecode Burn-In Inserter User Manual

Page 23

Advertising
background image

9391-TCB-OM (V1.3)

9391-TCB PRODUCT MANUAL

2-5

Installation and Setup

Connecting To 3-Wire Phoenix Terminal Connectors

Connecting To 3-Wire Phoenix Terminal Connectors

Figure 2-2 shows connections to the card 3-wire Phoenix™ terminal block
connectors. These connectors are used for card RS-485 LTC I/O connections.
These terminal blocks use a removable screw terminal binding post block
which allows easier access to the screw terminals.

Note:

It is preferable to wire connections to Phoenix plugs oriented as shown in
Figure 2-2

rather than assessing polarity on rear module connectors. Note

that the orientation of rear module connectors is not necessarily consistent
within a rear module, or between different rear modules. If wiring is first con-
nected to Phoenix plug oriented as shown here, the electrical orientation will
be correct regardless of rear module connector orientation.

Note:

An RS-485 input received by the card must have the customary zero-crossing
associated with RS-485. If the LTC source is offset above or below ground (0
V), the sources must be capacitively coupled or passed through an analog
audio DA that can restore zero-crossing.

Figure 2-2 3-Wire Phoenix Terminal Connections

A (-)

B (+)

G

RS-485

Removable Phoenix plug view oriented
with top (screw terminals) up

Note: RS-485 communication will not work if

any of the connections are reversed from
that shown here.

Rear module

PCB connector

RS-485 LTC Port Connections