Table 3-3

Troubleshooting Processing Errors by Symptom

Symptom

Error/Condition

Corrective Action

DashBoard™ shows Video

yellow icon and Input Invalid
message in 9391 Card Info
pane.

• Card edge Input Format LEDs

show continuous cycling.

No video input present

Make certain intended video source is
connected to appropriate 9391 card video
input. Make certain BNC cable connections
between frame Rear I/O Module for the card
and signal source are OK.

DashBoard™ shows invalid

in Ref Status message in 9391
Card Info pane.

Reference not properly
selected or not being received
(card has reverted to free-run
failover)

If external reference is not intended to be used,
make certain the Reference selection list is set
to appropriate alternate selection as desired.

Transient video or audio errors
(CRC, etc.) noted in viewing or
on logging waveform monitor.

Card reference cannot sync
with received video input

Reference Selection control must be
appropriately set to match upstream video
signal timing:

• If input video is not locked to a frame

reference, the 9391 should be set to lock to
input video (SDI A).

• If the video input is locked to a frame

reference, the 9391 should be set to lock to
the same reference (Reference 1 or
Reference 2
).

RS-485 LTC not being locked on
to by card (yellow status
indicator).

• LTC RS-485 polarity

incorrect

• LTC RS-485 does not have

zero-crossing per RS-485
convention

• Make certain RS-485 LTC connections are

as described in Connecting To 3-Wire
Phoenix Terminal Connectors (p. 2-5) i
n
Chapter 2, Installation and Setup.

• The RS-485 inputs received by the card must

have the customary zero-crossing associated
with RS-485. If the LTC source is offset
above or below ground (0 V), the sources
must be capacitively coupled or passed
through an analog audio DA that can restore
zero-crossing.

ERROR displayed on Timecode
Output Status.

Free-run selected as prioritized
manual selection, but timecode
generator is set to bypass

If free-run timecode is set as first prioritized
selection (i.e., free-run over any other choice),
Timecode Passthrough on Video Path >
Master Controls must be set to TC Gen On.

Advertising