Table 22. Programmable Output Active States

REGISTER

ADDRESS

EEPROM

MEMORY

ADDRESS

BIT

RANGE

DESCRIPTION

[0]

PO1 (MAX6870 only). 0 = active-low, 1 = active-high.

[1]

PO2 (MAX6870 only). 0 = active-low, 1 = active-high.

[2]

PO3 (MAX6870)/PO1 (MAX6871). 0 = active-low, 1 = active-high.

[3]

PO4 (MAX6870)/PO2 (MAX6871). 0 = active-low, 1 = active-high.

[4]

PO5 (MAX6870)/PO3 (MAX6871). 0 = active-low, 1 = active-high.

[5]

PO6 (MAX6870)/PO4 (MAX6871). 0 = active-low, 1 = active-high.

[6]

PO7 (MAX6870)/PO5 (MAX6871). 0 = active-low, 1 = active-high.

3Ah

803Ah

[7]

PO8 (MAX6870 only). 0 = active-low, 1 = active-high.

REGISTER

ADDRESS

EEPROM

MEMORY

ADDRESS

BIT

RANGE

AFFECTED

OUTPUT

DESCRIPTION

11h

8011h

[6:4]

PO1

15h

8015h

[6:4]

PO2

1Ch

801Ch

[7:5]

PO3

23h

8023h

[7:5]

PO4

000 = open-drain, 001 = weak pullup to IN3, 010 = weak pullup to IN4,
011 = weak pullup to IN5, 100 = weak pullup to IN6, 101 = weak pullup to
ABP, 110 = charge-pump output, 111 = not used.

2Ah

802Ah

[7:4]

PO5

31h

8031h

[7:4]

PO6

35h

8035h

[7:4]

PO7

39h

8039h

[7:4]

PO8

0000 = open-drain, 0001 = weak pullup to IN3, 0010 = weak pullup to IN4,
0011 = weak pullup to IN5, 0100 = weak pullup to IN6, 0101 = weak pullup to
ABP, 0110 = push-pull to IN3, 0111 = push-pull to IN4, 1000 = push-pull to
IN5, 1001 = push-pull to IN6, 1010 through 1111 = not used.

Table 23. Programmable Output Stage Options (MAX6870)

Table 24. Programmable Output Stage Options (MAX6871)

REGISTER

ADDRESS

EEPROM

MEMORY

ADDRESS

BIT

RANGE

AFFECTED

OUTPUT

DESCRIPTION

1Ch

801Ch

[7:5]

PO1

23h

8023h

[7:5]

PO2

000 = open-drain, 001 = weak pullup to IN3, 010 = weak pullup to IN4,
011–100 = not used, 101 = weak pullup to ABP, 110 = charge-pump output,
111 = not used.

2Ah

802Ah

[7:4]

PO3

31h

8031h

[7:4]

PO4

35h

8035h

[7:4]

PO5

0000 = open-drain, 0001 = weak pullup to IN3, 0010 = weak pullup to IN4,
0011–0100 = not used, 0101 = weak pullup to ABP, 0110 = push-pull to IN3,
0111 = push-pull to IN4, 1000–1111 = not used.